GENERATORS
Take a look at our selection of quality KUBOTA generators that will work in both residential and commercial settings!
GL-7000
- Prime Output 6.5 kW
- Standby Output 7 kW
- Frequency: 60 HZ
- Phase: Single
Improved Reliability
- Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
- Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.
Easy Maintenance
- One-side maintenance to reduce the operator’s work load.
- Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.
Safety Features
- Protective covers on all moving parts (for the engine’s cooling fan and the generator).
- Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.
Wide Application
- Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
- An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
| Type | – | Rotating field single-phase AC generator |
| Frequency | Hz | 60 |
| Standby Output | kVA (kW) | 7.0 (7.0) |
| Prime Output | kVA (kW) | 6.5 (6.5) |
| Voltage – Single Phase | V | 110/220 |
| Armature Connection | – | Series |
| Phase/Wire | – | 4-Jan |
| Power Factor | – | 1 |
| No. of Poles | – | 2 |
| Insulation | Class | Rotor coil; class F, Stator coil; class B |
| Type of Coupling | – | Direct coupled |
| AMPS | ||
| Single Phase 110V | A | 59.1 |
| Single Phase 220V | A | 29.5 |
| No. of Receptacles | ||
| 5-15R | – | 2 |
| 5-20RA (GFCI) | – | N/A |
| L5-30R | – | N/A |
| L6-30R | – | N/A |
| L14-30R | – | N/A |
| CS-6369 | – | N/A |
| Terminal | ||
| Terminal | – | Available |
| Diesel Engine | ||
| Type | – | Vertical, water-cooled, 4-cycle diesel engine |
| Model | – | Z482 |
| No. of Cylinders | – | 2 |
| Bore x Stroke | mm (in.) | 67.0 x 68.0 (2.6 x 2.7) |
| Displacement | L (cu. in.) | 0.479 (29.2) |
| Engine Speed | rpm | 3600 |
| Lubricant (API classification) | – | Above CD grade |
| Oil Capacity | L (qts.) | 2.2 (0.58) |
| Coolant Capacity | L (qts.) | 3.7 (0.98) |
| Starting System | – | Electric – 12 volt DC |
| SET | ||
| Fuel Consumption | – | Diesel fuel No.2 (ASTM D975) |
| at Full Load | L/h (gal./h) | 2.6 (0.69) |
| at 3/4 Load | L/h (gal./h) | 2.1 (0.55) |
| at 1/2 Load | L/h (gal./h) | 1.7 (0.45) |
| at 1/4 Load | L/h (gal./h) | 1.4 (0.38) |
| Fuel Tank Capacity – Continuous Operation Hours | L (gal.) | 28.0 (7.4) |
| at Full Load | h | 10 |
| at 3/4 Load | h | 13.3 |
| at 1/2 Load | h | 16.5 |
| at 1/4 Load | h | 20 |
| Battery (Ah/5 h) | – | 38B20R (12 V x 28 Ah) |
| Dimensions L x W x H | mm (in.) | 1066 x 618 x 698 (42.0 x 24.3 x 27.5) |
| Approx. Net Weight | kg (lbs.) | 235 (518) |
| Sound Level (Full Load at 23 ft. [7m]) | dB (A) | 66 |
| Emergency Stop System | – | In case of abnormal: Oil pressure, water temperature, or When the access terminal cover is opened |
GL7000-TM
- Prime Output 6.5 kVA
- Standby Output 7 kVA
- Frequency: 60 HZ
- Phase: Single
Improved Reliability
- Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
- Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.
Easy Maintenance
- One-side maintenance to reduce the operator’s work load.
- Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.
Safety Features
- Protective covers on all moving parts (for the engine’s cooling fan and the generator).
- Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.
Wide Application
- Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
- An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
Not Available Online. Contact For Information.
GL-11000
- Prime Output 10.0 kVA (10.0 kW)
- Standby Output 11.0 kVA (11.0 kW)
- Frequency: 60 HZ
- Phase: Single
Improved Reliability
- Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
- Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.
Easy Maintenance
- One-side maintenance to reduce the operator’s work load.
- Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.
Safety Features
- Protective covers on all moving parts (for the engine’s cooling fan and the generator).
- Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.
Wide Application
- Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
- An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
| Type | – | Rotating field single-phase AC generator |
| Frequency | Hz | 60 |
| Standby Output | kVA (kW) | 11.0 (11.0) |
| Prime Output | kVA (kW) | 10.0 (10.0) |
| Voltage – Single Phase | V | 110/220 |
| Armature Connection | – | Series |
| Phase / Wire | – | 3-Jan |
| Power Factor | – | 1 |
| No. of Poles | – | 2 |
| Insulation | Class | Rotor coil; class F, Stator coil; class B |
| Type of Coupling | – | Direct coupled |
| AMPS | ||
| Single Phase 110V | A | 90.9 |
| Single Phase 220V | A | 45.5 |
| NO. OF RECEPTACLES | ||
| 5-15R | – | 2 |
| 5-20RA (GFCI) | – | N/A |
| L5-30R | – | N/A |
| L6-30R | – | N/A |
| L14-30R | – | N/A |
| CS-6369 | – | N/A |
| TERMINAL | ||
| Terminal | – | Available |
| DIESEL ENGINE | ||
| Type | – | Vertical, water-cooled, 4-cycle diesel engine |
| Model | – | D722 |
| No. of Cylinders | – | 3 |
| Bore x Stroke | mm (in.) | 67.0 x 68.0 (2.6 x 2.7) |
| Displacement | L (cu. in.) | 0.719 (43.9) |
| Engine Speed | rpm | 3600 |
| Continuous Rated Output | kW (HP) | 12.2 (16.3) |
| Lubricant (API classification) | – | Above CD grade |
| Oil Capacity | L (qts.) | 3.4 (0.9) |
| Coolant Capacity | L (qts.) | 4.1 (1.1) |
| Starting System | – | Electric – 12 volt DC |
| SET | ||
| Fuel Consumption | – | Diesel fuel No.2 (ASTM D975) |
| at Full Load | L/h (gal./h) | 4.1 (1.09) |
| at 3/4 Load | L/h (gal./h) | 3.3 (0.86) |
| at 1/2 Load | L/h (gal./h) | 2.7 (0.71) |
| at 1/4 Load | L/h (gal./h) | 2.2 (0.59) |
| Fuel Tank Capacity Continuous Operation Hours Continuous Operation Hours | L (gal.) | 28.0 (7.4) |
| at Full Load | h | 7 |
| at 3/4 Load | h | 8.5 |
| at 1/2 Load | h | 10.4 |
| at 1/4 Load | h | 12.7 |
| Battery (Ah/5 h) | – | 55B24R (12 V x 36 Ah) |
| Dimensions L x W x H | mm (in.) | 1281 x 618 x 698 (50.4 x 24.3 x 27.5) |
| Approx. Net Weight | kg (lbs.) | 295 (650) |
| Sound Level (Full Load at 23 ft. [7m]) | dB (A) | 68 |
| Emergency Stop System | – | In case of abnormal: Oil pressure, water temperature, or When the access terminal cover is opened |
GL11000-TM
- Prime Output 10 kVA
- Standby Output 11 kVA
- Frequency: 60 HZ
- Phase: Single
Improved Reliability
- Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
- Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.
Easy Maintenance
- One-side maintenance to reduce the operator’s work load.
- Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.
Safety Features
- Protective covers on all moving parts (for the engine’s cooling fan and the generator).
- Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.
Wide Application
- Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
- An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
Not Available Online. Contact For Information.
GL14000
- Prime Output 12 kVA
- Standby Output 14 kVA
- Frequency: 60 HZ
- Phase: Single
Improved Reliability
- Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
- Large-capacity fuel tank (36.4L / 9.62 U.S gal.) enables longer continuous operation on a single tank.
Easy Maintenance
- One-side maintenance to reduce the operator’s work load.
- Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.
Safety Features
- Protective covers on all moving parts (for the engine’s cooling fan and the generator).
- Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.
Wide Application
- Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
- An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
| Frequency | Hz | 60 |
| Rated Output | kVA | 12 |
| Maximum Output | kVA | 14 |
| Rated Voltage | V | 240 / 120 |
| Rated Current | A | 100 |
| Phase / Wire | 1-3 | |
| Power Factor | 1.0 | |
| Frequency Regulation | % | 0.25 |
| Voltage Regulation | % | 240V: ±0.5 / 120V: ±5.0 |
| Momentary Load Variability | % | Fluctuation rate of the maximum voltage: 30% Within 3% of the setting voltage Recovery time: 2 seconds |
| Voltage Adjusting Range | % | -15%~+5% of the rated voltage |
| Waveform Distortion Factor (at no load) | % | 2.0 |
| RECEPTACLES & TERMINAL | ||
| Receptacles | 120V-20A GFCI x 2 (4 receptacles) 120/240V-50A Twist type x 1 |
|
| Breaker | Main x 1 Secondary In-line x2 |
|
| Output Terminal Block | Single phase – 3 wires (U-N/G-W) Terminal Size: M8 |
|
| Padlock (Option) | Front Door Lock, Side Door Lock, Fuel Inlet Lock, Terminal Cover | |
| DIESEL ENGINE | ||
| Model | Kubota / D902 | |
| Engine Speed | RPM | 3600 |
| Applicable Emission Control Standard | EPA Tier 4 Final, CARB | |
| GENERATOR CONTROL PANEL | ||
| Voltmeter, Ammeter, Frequency Meter | Standard | |
| Ammeter Selector Switch | Standard | |
| Voltage Adjusting Dial | Standard | |
| Available Output Indicator | Standard | |
| Voltage Indicator Panel Light | Standard | |
| Hour Meter, Fuel Gauge, Tachometer | Standard | |
| RELIABILITY & SAFETY | ||
| Minimum Insulation Resistance | (MΩ) | 3 |
| Withstand Voltage Test Procedure | 1500V, within 1 minute | |
| Overcurrent Protective Device | Equipped as standard | |
| Grounding System | Neutral Bonding (Body earthing) | |
| Engine Shut-Off | Low Oil Pressure, Excessive Coolant Temperature, Improper Charging, Over Revolution | |
| Spill Containment Capacity | L | 82 (186% of the entire fuel, oil and coolant) |
| Emergency Stop System | Opening of control panel or terminal cover | |
| SET | ||
| Fuel Consumption at Full Load | L/h (Gal/hr) | 4.9 (1.29) |
| Fuel Consumption at 3/4 Load | L/h (Gal/hr) | 3.9 (1.03) |
| Fuel Consumption at 1/2 Load | L/h (Gal/hr) | 3.2 (0.85) |
| Fuel Consumption at 1/4 Load | L/h (Gal/hr) | 2.5 (0.66) |
| Fuel Tank Capacity (Net Volume) | L (gal) | 36.4 (9.62) |
| Continuous Operating Hours at Full Load | (hr) | 7.0 |
| Continuous Operating Hours at 3/4 Load | (hr) | 9.0 |
| Continuous Operating Hours at 1/2 Load | (hr) | 11.0 |
| Continuous Operating Hours at 1/4 Load | (hr) | 15.0 |
| Dimensions LxWxH | mm (in.) | 1310 x 640 x 895 (51.57 x 25.2 x 35.24) |
| Dry Weight / Net Weight | kg (lbs.) | 410 (904) / 455 (1003) |
| Noise Level (No Load / Rated Operation) | (dB • A/7 m) | 65 / 67 |