GENERATORS

Take a look at our selection of quality KUBOTA generators that will work in both residential and commercial settings!

GL-7000

  • Prime Output 6.5 kW
  • Standby Output 7 kW
  • Frequency: 60 HZ
  • Phase: Single

Improved Reliability

  • Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
  • Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.

Easy Maintenance

  • One-side maintenance to reduce the operator’s work load.
  • Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.

Safety Features

  • Protective covers on all moving parts (for the engine’s cooling fan and the generator).
  • Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.

Wide Application

  • Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
  • An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
Type Rotating field single-phase AC generator
Frequency Hz 60
Standby Output kVA (kW) 7.0 (7.0)
Prime Output kVA (kW) 6.5 (6.5)
Voltage – Single Phase V 110/220
Armature Connection Series
Phase/Wire 4-Jan
Power Factor 1
No. of Poles 2
Insulation Class Rotor coil; class F, Stator coil; class B
Type of Coupling Direct coupled
AMPS
Single Phase 110V A 59.1
Single Phase 220V A 29.5
No. of Receptacles
5-15R 2
5-20RA (GFCI) N/A
L5-30R N/A
L6-30R N/A
L14-30R N/A
CS-6369 N/A
Terminal
Terminal Available
Diesel Engine
Type Vertical, water-cooled, 4-cycle diesel engine
Model Z482
No. of Cylinders 2
Bore x Stroke mm (in.) 67.0 x 68.0 (2.6 x 2.7)
Displacement L (cu. in.) 0.479 (29.2)
Engine Speed rpm 3600
Lubricant (API classification) Above CD grade
Oil Capacity L (qts.) 2.2 (0.58)
Coolant Capacity L (qts.) 3.7 (0.98)
Starting System Electric – 12 volt DC
SET
Fuel Consumption Diesel fuel No.2 (ASTM D975)
at Full Load L/h (gal./h) 2.6 (0.69)
at 3/4 Load L/h (gal./h) 2.1 (0.55)
at 1/2 Load L/h (gal./h) 1.7 (0.45)
at 1/4 Load L/h (gal./h) 1.4 (0.38)
Fuel Tank Capacity – Continuous Operation Hours L (gal.) 28.0 (7.4)
at Full Load h 10
at 3/4 Load h 13.3
at 1/2 Load h 16.5
at 1/4 Load h 20
Battery (Ah/5 h) 38B20R (12 V x 28 Ah)
Dimensions L x W x H mm (in.) 1066 x 618 x 698 (42.0 x 24.3 x 27.5)
Approx. Net Weight kg (lbs.) 235 (518)
Sound Level (Full Load at 23 ft. [7m]) dB (A) 66
Emergency Stop System In case of abnormal: Oil pressure, water temperature, or When the access terminal cover is opened

GL7000-TM

  • Prime Output 6.5 kVA
  • Standby Output 7 kVA
  • Frequency: 60 HZ
  • Phase: Single

Improved Reliability

  • Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
  • Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.

Easy Maintenance

  • One-side maintenance to reduce the operator’s work load.
  • Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.

Safety Features

  • Protective covers on all moving parts (for the engine’s cooling fan and the generator).
  • Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.

Wide Application

  • Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
  • An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.

Not Available Online. Contact For Information.

GL-11000

  • Prime Output 10.0 kVA (10.0 kW)
  • Standby Output 11.0 kVA (11.0 kW)
  • Frequency: 60 HZ
  • Phase: Single

Improved Reliability

  • Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
  • Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.

Easy Maintenance

  • One-side maintenance to reduce the operator’s work load.
  • Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.

Safety Features

  • Protective covers on all moving parts (for the engine’s cooling fan and the generator).
  • Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.

Wide Application

  • Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
  • An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
Type Rotating field single-phase AC generator
Frequency Hz 60
Standby Output kVA (kW) 11.0 (11.0)
Prime Output kVA (kW) 10.0 (10.0)
Voltage – Single Phase V 110/220
Armature Connection Series
Phase / Wire 3-Jan
Power Factor 1
No. of Poles 2
Insulation Class Rotor coil; class F, Stator coil; class B
Type of Coupling Direct coupled
AMPS
Single Phase 110V A 90.9
Single Phase 220V A 45.5
NO. OF RECEPTACLES
5-15R 2
5-20RA (GFCI) N/A
L5-30R N/A
L6-30R N/A
L14-30R N/A
CS-6369 N/A
TERMINAL
Terminal Available
DIESEL ENGINE
Type Vertical, water-cooled, 4-cycle diesel engine
Model D722
No. of Cylinders 3
Bore x Stroke mm (in.) 67.0 x 68.0 (2.6 x 2.7)
Displacement L (cu. in.) 0.719 (43.9)
Engine Speed rpm 3600
Continuous Rated Output kW (HP) 12.2 (16.3)
Lubricant (API classification) Above CD grade
Oil Capacity L (qts.) 3.4 (0.9)
Coolant Capacity L (qts.) 4.1 (1.1)
Starting System Electric – 12 volt DC
SET
Fuel Consumption Diesel fuel No.2 (ASTM D975)
at Full Load L/h (gal./h) 4.1 (1.09)
at 3/4 Load L/h (gal./h) 3.3 (0.86)
at 1/2 Load L/h (gal./h) 2.7 (0.71)
at 1/4 Load L/h (gal./h) 2.2 (0.59)
Fuel Tank Capacity Continuous Operation Hours Continuous Operation Hours L (gal.) 28.0 (7.4)
at Full Load h 7
at 3/4 Load h 8.5
at 1/2 Load h 10.4
at 1/4 Load h 12.7
Battery (Ah/5 h) 55B24R (12 V x 36 Ah)
Dimensions L x W x H mm (in.) 1281 x 618 x 698 (50.4 x 24.3 x 27.5)
Approx. Net Weight kg (lbs.) 295 (650)
Sound Level (Full Load at 23 ft. [7m]) dB (A) 68
Emergency Stop System In case of abnormal: Oil pressure, water temperature, or When the access terminal cover is opened

GL11000-TM

  • Prime Output 10 kVA
  • Standby Output 11 kVA
  • Frequency: 60 HZ
  • Phase: Single

Improved Reliability

  • Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
  • Large-capacity fuel tank (28L/7.4 U.S. gal.) enables longer continuous operation on a single tank.

Easy Maintenance

  • One-side maintenance to reduce the operator’s work load.
  • Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.

Safety Features

  • Protective covers on all moving parts (for the engine’s cooling fan and the generator).
  • Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.

Wide Application

  • Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
  • An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.

Not Available Online. Contact For Information.

GL14000

  • Prime Output 12 kVA
  • Standby Output 14 kVA
  • Frequency: 60 HZ
  • Phase: Single

Improved Reliability

  • Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
  • Large-capacity fuel tank (36.4L / 9.62 U.S gal.) enables longer continuous operation on a single tank.

Easy Maintenance

  • One-side maintenance to reduce the operator’s work load.
  • Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.

Safety Features

  • Protective covers on all moving parts (for the engine’s cooling fan and the generator).
  • Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.

Wide Application

  • Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
  • An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
Frequency Hz 60
Rated Output kVA 12
Maximum Output kVA 14
Rated Voltage V 240 / 120
Rated Current A 100
Phase / Wire 1-3
Power Factor 1.0
Frequency Regulation % 0.25
Voltage Regulation % 240V: ±0.5 / 120V: ±5.0
Momentary Load Variability % Fluctuation rate of the maximum voltage: 30%
Within 3% of the setting voltage Recovery time: 2 seconds
Voltage Adjusting Range % -15%~+5% of the rated voltage
Waveform Distortion Factor (at no load) % 2.0
RECEPTACLES & TERMINAL
Receptacles 120V-20A GFCI x 2 (4 receptacles)
120/240V-50A Twist type x 1
Breaker Main x 1
Secondary In-line x2
Output Terminal Block Single phase – 3 wires (U-N/G-W)
Terminal Size: M8
Padlock (Option) Front Door Lock, Side Door Lock, Fuel Inlet Lock, Terminal Cover
DIESEL ENGINE
Model Kubota / D902
Engine Speed RPM 3600
Applicable Emission Control Standard EPA Tier 4 Final, CARB
GENERATOR CONTROL PANEL
Voltmeter, Ammeter, Frequency Meter Standard
Ammeter Selector Switch Standard
Voltage Adjusting Dial Standard
Available Output Indicator Standard
Voltage Indicator Panel Light Standard
Hour Meter, Fuel Gauge, Tachometer Standard
RELIABILITY & SAFETY
Minimum Insulation Resistance (MΩ) 3
Withstand Voltage Test Procedure 1500V, within 1 minute
Overcurrent Protective Device Equipped as standard
Grounding System Neutral Bonding (Body earthing)
Engine Shut-Off Low Oil Pressure, Excessive Coolant Temperature, Improper Charging, Over Revolution
Spill Containment Capacity L 82 (186% of the entire fuel, oil and coolant)
Emergency Stop System Opening of control panel or terminal cover
SET
Fuel Consumption at Full Load L/h (Gal/hr) 4.9 (1.29)
Fuel Consumption at 3/4 Load L/h (Gal/hr) 3.9 (1.03)
Fuel Consumption at 1/2 Load L/h (Gal/hr) 3.2 (0.85)
Fuel Consumption at 1/4 Load L/h (Gal/hr) 2.5 (0.66)
Fuel Tank Capacity (Net Volume) L (gal) 36.4 (9.62)
Continuous Operating Hours at Full Load (hr) 7.0
Continuous Operating Hours at 3/4 Load (hr) 9.0
Continuous Operating Hours at 1/2 Load (hr) 11.0
Continuous Operating Hours at 1/4 Load (hr) 15.0
Dimensions LxWxH mm (in.) 1310 x 640 x 895 (51.57 x 25.2 x 35.24)
Dry Weight / Net Weight kg (lbs.) 410 (904) / 455 (1003)
Noise Level (No Load / Rated Operation) (dB • A/7 m) 65 / 67